2024 February

From EOVSA Wiki
Jump to navigation Jump to search

February 1

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to Hydraulic fault on 27m antenna.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified.

Events

Solar activity is moderate. 1 C-class flare observed by EOVSA at 22:33 UT. See dynamic spectra at this link.

February 2

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to Hydraulic fault on 27m antenna.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified.

Events

Solar activity is moderate. 2 C-class flares observed by EOVSA at 16:30 and 16:47 UT. See dynamic spectra at this link.

February 3

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to Hydraulic fault on 27m antenna.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified.

Events

Solar activity is moderate.

February 4

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to Hydraulic fault on 27m antenna.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified.

Events

Solar activity is moderate. 2 M-class flares observed by EOVSA at 20:55 and 22:27 UT. See dynamic spectra at this link.

February 5

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to Hydraulic fault on 27m antenna.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified.

Events

Solar activity is moderate. 2 C-class flares observed by EOVSA at 23:06 UT. See dynamic spectra at this link.

February 6

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to Hydraulic fault on 27m antenna.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 12 Due to a sequence of cloud days the solar power station was unable to charge the batteries
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified.

Events

Solar activity is moderate. 1 M-class and 1 C-class flares observed by EOVSA at 17:34 and 18:45 UT. See dynamic spectra at this link.

February 7

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to Hydraulic fault on 27m antenna.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified.

Events

Solar activity is moderate. 1 M-class and 1 C-class flares observed by EOVSA at 17:52 and 20:25 UT. See dynamic spectra at this link.

February 8

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to Hydraulic fault on 27m antenna.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified.

Events

Solar activity is moderate. 2 M-class and 2 C-class flares observed by EOVSA at 17:05, 17:36, 19:02 and 23:32 UT. See dynamic spectra at this link.

February 9

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to Hydraulic fault on 27m antenna.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified.

Events

Solar activity is moderate. 2 M-class and 1 C-class flares observed by EOVSA at 00:09, 17:25 and 17:56. See dynamic spectra at this link.

February 10

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to Hydraulic fault on 27m antenna.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified.

Events

Solar activity is moderate. 1 M-class and 5 C-class flares observed by EOVSA at 18:18, 20:46, 21:07, 22:47, 23:04 and 23:57. See dynamic spectra at this link.

February 11

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to Hydraulic fault on 27m antenna.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified.

Events

Solar activity is moderate. 1 C-class flare observed by EOVSA at 20:20 UT. See dynamic spectra at this link.

February 12

Observer on duty: Caius Selhorst

Calibrations

The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified.

Events

Solar activity is moderate. 1 M-class and 1 C-class flares observed by EOVSA at 15:54 and 17:34 UT. See dynamic spectra at this link.


February 13

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to the 27 m wrong receiver position. No calibrations until the fault is rectified.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified.

Events

Solar activity is moderate.

February 14

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to the 27 m wrong receiver position. No calibrations until the fault is rectified.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified.

Events

Solar activity is moderate. 1 C-class flare observed by EOVSA at 17:55 UT. See dynamic spectra at this link.


February 15

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to the 27 m wrong receiver position. No calibrations until the fault is rectified.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified.

Events

Solar activity is moderate.

February 16

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to the 27 m wrong receiver position. No calibrations until the fault is rectified.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified.

Events

Solar activity is moderate. 1 M-class and 1 C-class flares observed by EOVSA at 16:20 and 22:05 UT. See dynamic spectra at this link.

February 17

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to the 27 m wrong receiver position. No calibrations until the fault is rectified.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified.

Events

Solar activity is moderate.

February 18

Observer on duty: Caius Selhorst

No Observations during the day due to a fail in the Helios computer.

February 19

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to the 27 m wrong receiver position. No calibrations until the fault is rectified.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified.

Events

Solar activity is moderate.

February 20

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to the 27 m wrong receiver position. No calibrations until the fault is rectified.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified.

Events

Solar activity is moderate. 1 C-class flare observed by EOVSA at 20:40 UT. See dynamic spectra at this link.

February 21

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to the 27 m wrong receiver position. No calibrations until the fault is rectified.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified.

Events

Solar activity is moderate. 1 X-class and 4 C-class flares observed by EOVSA at 17:14, 18:17, 20:33, 22:41 and 23:04 UT. See dynamic spectra at this link.

February 22

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to the 27 m wrong receiver position. No calibrations until the fault is rectified.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified.

Events

Solar activity is moderate. 1 X-class, 1-M class and 1 C-class flares observed by EOVSA at 17:53, 20:40 and 22:32 UT. See dynamic spectra at this link.

February 23

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to the 27 m wrong receiver position. No calibrations until the fault is rectified.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified.

Events

Solar activity is moderate. 3 M-class and 3 C-class flares observed by EOVSA at 15:45, 16:17, 17:40, 20:25, 21:12 and 23:12 UT. See dynamic spectra at this link.


February 24

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to the 27 m wrong receiver position. No calibrations until the fault is rectified.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified.

Events

Solar activity is moderate. 1 C-class flare observed by EOVSA at 17:16 UT. See dynamic spectra at this link.


February 25

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to the 27 m wrong receiver position. No calibrations until the fault is rectified.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified.

Events

Solar activity is moderate. 1 M-class flare observed by EOVSA at 17:06 UT. See dynamic spectra at this link.


February 26

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to the 27 m wrong receiver position. No calibrations until the fault is rectified.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified.

Events

Solar activity is moderate.2 C-class flares observed by EOVSA at 20:44 and 21:53 UT. See dynamic spectra at this link.


February 27

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to the 27 m wrong receiver position. No calibrations until the fault is rectified.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified.

Events

Solar activity is moderate.

February 28

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to the 27 m wrong receiver position. No calibrations until the fault is rectified.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified.

Events

Solar activity is moderate. 1 M-class flare observed by EOVSA at 18:04 UT. See dynamic spectra at this link.

February 29

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to the 27 m wrong receiver position. No calibrations until the fault is rectified. Most of the day without observation due to a memory test on Helios.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified.

Events

Solar activity is moderate.