2024 January

From EOVSA Wiki
Jump to navigation Jump to search

January 01

Observer on duty: Caius Selhorst

Calibrations

Start Time (UT) Duration (min) Antenna(s) Comments/Reasons
--:-- --.-- -- Unsuccessful Reference calibration; Unknown reasons.
--:-- --.-- -- Unsuccessful Phase calibration; Unknown reasons.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 13 On Saturday, Nov 11 at 23:50 UT, The Ant13 shed was broken into and the cable from the solar cell batteries to the inverter was cut. Ant13 will remain off line until a replacement cable can be purchased.

Events

Solar activity is moderate.

January 02

Observer on duty: Owen Giersch

Calibrations

Start Time (UT) Duration (min) Antenna(s) Comments/Reasons
23:46 79.1 1-9, 11-12 Reference calibration successful; written to SQL (16:00 UT).
17:20 15.5 1-9, 11-12 Phase calibration successful; written to SQL.
22:14 15.5 1-9, 11-12 Phase calibration successful; written to SQL.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 13 On Saturday, Nov 11 at 23:50 UT, The Ant13 shed was broken into and the cable from the solar cell batteries to the inverter was cut. Ant13 will remain off line until a replacement cable can be purchased.

Events

Solar activity is moderate. 1 M-class and 1 C-class flares observed by EOVSA at 18:10 and 22:01 UT. See dynamic spectra at this link.

January 03

Observer on duty: Owen Giersch

Calibrations

Start Time (UT) Duration (min) Antenna(s) Comments/Reasons
23:46 80.1 1-9, 11-12 Reference calibration successful; written to SQL.
17:20 15.7 1-9, 11-12 Phase calibration successful; written to SQL.
22:14 15.5 1-9, 11-12 Phase calibration successful; written to SQL.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 13 On Saturday, Nov 11 at 23:50 UT, The Ant13 shed was broken into and the cable from the solar cell batteries to the inverter was cut. Ant13 will remain off line until a replacement cable can be purchased.

Events

Solar activity is moderate. 1 C-class and 1 B-class flares observed by EOVSA at 17:50 and 19:45 UT. See dynamic spectra at this link.

January 04

Observer on duty: Owen Giersch

Calibrations

Start Time (UT) Duration (min) Antenna(s) Comments/Reasons
14:52 79.2 1-9, 11-12 Reference calibration successful; written to SQL.
17:16 15.7 1-9, 11-12 Phase calibration successful; written to SQL.
22:14 15.5 1-9, 11-12 Phase calibration successful; written to SQL.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 13 On Saturday, Nov 11 at 23:50 UT, The Ant13 shed was broken into and the cable from the solar cell batteries to the inverter was cut. Ant13 will remain off line until a replacement cable can be purchased.

Events

Solar activity is moderate.

January 05

Observer on duty: Owen Giersch

Calibrations

No Calibrations due to Windscram

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 13 On Saturday, Nov 11 at 23:50 UT, The Ant13 shed was broken into and the cable from the solar cell batteries to the inverter was cut. Ant13 will remain off line until a replacement cable can be purchased.

Events

Solar activity is moderate.

January 06

Observer on duty: Owen Giersch

Calibrations

No Calibrations due to Windscram

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 13 On Saturday, Nov 11 at 23:50 UT, The Ant13 shed was broken into and the cable from the solar cell batteries to the inverter was cut. Ant13 will remain off line until a replacement cable can be purchased.

Events

Solar activity is moderate. 2 C-class flares observed by EOVSA at 16:30 and 21:57 UT. See dynamic spectra at this link.

January 07

Observer on duty: Owen Giersch

Calibrations

Start Time (UT) Duration (min) Antenna(s) Comments/Reasons
14:52 78.4 1-2, 4-6, 8-9, 11-12 Reference calibration successful; written to SQL.
17:14 15.6 1-2, 4-6, 8-9, 11-12 Phase calibration successful; written to SQL.
22:14 15.6 1-2, 4-6, 8-9, 11-12 Phase calibration successful; written to SQL.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link.
00:00 23:59 10 It has no VPOL power probably due to a failed optical link.
00:00 23:59 13 On Saturday, Nov 11 at 23:50 UT, The Ant13 shed was broken into and the cable from the solar cell batteries to the inverter was cut. Ant13 will remain off line until a replacement cable can be purchased.

Events

Solar activity is moderate.

January 08

Observer on duty: Owen Giersch

Calibrations

No Calibrations due to Windscram.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link.
00:00 23:59 10 It has no VPOL power probably due to a failed optical link.
00:00 23:59 13 On Saturday, Nov 11 at 23:50 UT, The Ant13 shed was broken into and the cable from the solar cell batteries to the inverter was cut. Ant13 will remain off line until a replacement cable can be purchased.

Events

Solar activity is moderate.

January 09

Observer on duty: Owen Giersch

Calibrations

No Calibrations due to Windscram.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link.
00:00 23:59 10 It has no VPOL power probably due to a failed optical link.
00:00 23:59 13 On Saturday, Nov 11 at 23:50 UT, The Ant13 shed was broken into and the cable from the solar cell batteries to the inverter was cut. Ant13 will remain off line until a replacement cable can be purchased.

Events

Solar activity is moderate.

January 10

Observer on duty: Owen Giersch

Calibrations

No Calibrations due to Hydraulic fault on 27m antenna.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 On Saturday, Nov 11 at 23:50 UT, The Ant13 shed was broken into and the cable from the solar cell batteries to the inverter was cut. Ant13 will remain off line until a replacement cable can be purchased.
00:00 23:59 14 On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified.

Events

Solar activity is moderate. 2 C-class flares observed by EOVSA at 18:20 and 19:00 UT. See dynamic spectra at this link.

January 11

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to Hydraulic fault on 27m antenna.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 On Saturday, Nov 11 at 23:50 UT, The Ant13 shed was broken into and the cable from the solar cell batteries to the inverter was cut. Ant13 will remain off line until a replacement cable can be purchased.
00:00 23:59 14 On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified.

Events

Solar activity is moderate. 1 C-class and 1 M-class flares observed by EOVSA at 17:51 and 20:12 UT. See dynamic spectra at this link.

January 12

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to Hydraulic fault on 27m antenna.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified.

Events

Solar activity is moderate.

January 13

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to Hydraulic fault on 27m antenna.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified.

Events

Solar activity is moderate.

January 14

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to Hydraulic fault on 27m antenna.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified.

Events

Solar activity is moderate.

January 15

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to Hydraulic fault on 27m antenna.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified.

Events

Solar activity is moderate.

January 16

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to Hydraulic fault on 27m antenna.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified.

Events

Solar activity is moderate.

January 17

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to Hydraulic fault on 27m antenna.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified.

Events

Solar activity is moderate.

January 18

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to Hydraulic fault on 27m antenna.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified.

Events

Solar activity is moderate.

January 19

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to Hydraulic fault on 27m antenna.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified.

Events

Solar activity is moderate.

January 20

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to Hydraulic fault on 27m antenna.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified.

Events

Solar activity is moderate.

January 21

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to Hydraulic fault on 27m antenna.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified.

Events

Solar activity is moderate. 1 C-class flare observed by EOVSA at 20:12 UT. See dynamic spectra at this link.

January 22

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to Hydraulic fault on 27m antenna.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified.

Events

Solar activity is moderate. 3 C-class flares observed by EOVSA at 19:18, 21:20 and 21:40 UT. See dynamic spectra at this link.

January 23

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to Hydraulic fault on 27m antenna.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified.

Events

Solar activity is moderate. 2 C-class flares observed by EOVSA at 17:38 and 21:03 UT. See dynamic spectra at this link.

January 24

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to Hydraulic fault on 27m antenna.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified.

Events

Solar activity is moderate. 1 M-class flare observed by EOVSA at 21:08 UT. See dynamic spectra at this link.

January 25

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to Hydraulic fault on 27m antenna.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified.

Events

Solar activity is moderate.

January 26

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to Hydraulic fault on 27m antenna.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified.

Events

Solar activity is moderate.

January 27

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to Hydraulic fault on 27m antenna.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified.

Events

Solar activity is moderate.

January 28

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to Hydraulic fault on 27m antenna.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified.

Events

Solar activity is moderate.

January 29

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to Hydraulic fault on 27m antenna.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified.

Events

Solar activity is moderate. 2 C-class flares observed by EOVSA at 16:38 and 22:31 UT. See dynamic spectra at this link.

January 30

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to Hydraulic fault on 27m antenna.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified.

Events

Solar activity is moderate. 1 C-class flare observed by EOVSA at 17:37 UT. See dynamic spectra at this link.

January 31

Observer on duty: Caius Selhorst

Calibrations

No Calibrations due to Hydraulic fault on 27m antenna.

Outages

Start Time (UT) End Time (UT) Antenna(s) Comments/Reasons
00:00 23:59 7 It has no VPOL power probably due to a failed optical link
00:00 23:59 10 It has no VPOL power probably due to a failed optical link
00:00 23:59 13 The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational.
00:00 23:59 14 On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified.

Events

Solar activity is moderate.