Daily observation notes published from the eovsadata canonical log.
February 01¶
Observer: Caius Selhorst
Solar activity: Solar activity is moderate.
Calibrations
No Calibrations due to Hydraulic fault on 27m antenna.
Issues and outages
| Time (UT) | Antennas | Details |
|---|---|---|
| 4 | Ant 4 FE Temp is out of range--no solution yet. | |
| 5 | Ant 5 has low VPOL power probably due to DCM issue | |
| 00:00–23:59 | 7 | Ant 7 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 10 | Ant 10 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 10 | Ant 10 FE Temp reporting bad temperature due to failed sensor. | |
| 14 | Ant 14 has a hydraulic leak and transformer failure. No calibrations / until it can be repaired. | |
| 12 | Ant 12 didn't stow - said no trips | |
| 00:00–23:59 | 13 | The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational. |
| 00:00–23:59 | 14 | On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified. |
Events
1 C-class flare observed by EOVSA at 22:33 UT. See dynamic spectra at this link.
Antenna availability: automatic assessment.
February 02¶
Observer: Caius Selhorst
Solar activity: Solar activity is moderate.
Calibrations
No Calibrations due to Hydraulic fault on 27m antenna.
Issues and outages
| Time (UT) | Antennas | Details |
|---|---|---|
| 4 | Ant 4 FE Temp is out of range--no solution yet. | |
| 5 | Ant 5 has low VPOL power probably due to DCM issue | |
| 00:00–23:59 | 7 | Ant 7 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 10 | Ant 10 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 10 | Ant 10 FE Temp reporting bad temperature due to failed sensor. | |
| 14 | Ant 14 has a hydraulic leak and transformer failure. No calibrations / until it can be repaired. | |
| 12 | Ant 12 didn't stow last night - said no trip | |
| 00:00–23:59 | 13 | The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational. |
| 00:00–23:59 | 14 | On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified. |
Events
2 C-class flares observed by EOVSA at 16:30 and 16:47 UT. See dynamic spectra at this link.
Antenna availability: automatic assessment.
February 03¶
Observer: Caius Selhorst
Solar activity: Solar activity is moderate.
Calibrations
No Calibrations due to Hydraulic fault on 27m antenna.
Issues and outages
| Time (UT) | Antennas | Details |
|---|---|---|
| 4 | Ant 4 FE Temp is out of range--no solution yet. | |
| 5 | Ant 5 has low VPOL power probably due to DCM issue | |
| 00:00–23:59 | 7 | Ant 7 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 10 | Ant 10 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 10 | Ant 10 FE Temp reporting bad temperature due to failed sensor. | |
| 14 | Ant 14 has a hydraulic leak and transformer failure. No calibrations / until it can be repaired. | |
| 12 | Ant 12 didn't stow last night - said no trip / Recording stopped with DPPXMP crash. Restarted at 16:24 UT. | |
| 00:00–23:59 | 13 | The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational. |
| 00:00–23:59 | 14 | On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified. |
Antenna availability: automatic assessment.
February 04¶
Observer: Caius Selhorst
Solar activity: Solar activity is moderate.
Calibrations
No Calibrations due to Hydraulic fault on 27m antenna.
Issues and outages
| Time (UT) | Antennas | Details |
|---|---|---|
| 4 | Ant 4 FE Temp is out of range--no solution yet. | |
| 5 | Ant 5 has low VPOL power probably due to DCM issue | |
| 00:00–23:59 | 7 | Ant 7 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 10 | Ant 10 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 10 | Ant 10 FE Temp reporting bad temperature due to failed sensor. | |
| 14 | Ant 14 has a hydraulic leak and transformer failure. No calibrations / until it can be repaired. | |
| 12 | Ant 12 didn't stow last night - said no trip | |
| 2 and 8 | Ant 2 and 8 front end temperature issues - tried to reset | |
| 00:00–23:59 | 13 | The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational. |
| 00:00–23:59 | 14 | On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified. |
Events
2 M-class flares observed by EOVSA at 20:55 and 22:27 UT. See dynamic spectra at this link.
Antenna availability: automatic assessment.
February 05¶
Observer: Caius Selhorst
Solar activity: Solar activity is moderate.
Calibrations
No Calibrations due to Hydraulic fault on 27m antenna.
Issues and outages
| Time (UT) | Antennas | Details |
|---|---|---|
| 00:00–23:59 | 7 | It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 10 | It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 13 | The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational. |
| 00:00–23:59 | 14 | On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified. |
Events
2 C-class flares observed by EOVSA at 23:06 UT. See dynamic spectra at this link.
Antenna availability: automatic assessment.
February 06¶
Observer: Caius Selhorst
Solar activity: Solar activity is moderate.
Calibrations
No Calibrations due to Hydraulic fault on 27m antenna.
Issues and outages
| Time (UT) | Antennas | Details |
|---|---|---|
| 00:00–23:59 | 7 | It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 10 | It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 12 | Due to a sequence of cloud days the solar power station was unable to charge the batteries |
| 00:00–23:59 | 13 | The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational. |
| 00:00–23:59 | 14 | On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified. |
Events
1 M-class and 1 C-class flares observed by EOVSA at 17:34 and 18:45 UT. See dynamic spectra at this link.
Observations
Imported source block (date does not match record 2024-02-06)
Tohban notes for Sun, Feb. 4- Tuesday Feb 6:
Ant 4 FE Temp is out of range--no solution yet.
Ant 5 has low VPOL power probably due to DCM issue
Ant 7 has no VPOL power probably due to a failed optical link.
Ant 10 has no VPOL power probably due to a failed optical link.
Ant 10 FE Temp reporting bad temperature due to failed sensor.
Ant 14 has a hydraulic leak and transformer failure. No calibrations
until it can be repaired.
Report problems here:
Ant12 off due to solar power station unable to charge batteries
because of cloud.
Antenna availability: automatic assessment.
February 07¶
Observer: Caius Selhorst
Solar activity: Solar activity is moderate.
Calibrations
No Calibrations due to Hydraulic fault on 27m antenna.
Issues and outages
| Time (UT) | Antennas | Details |
|---|---|---|
| 00:00–23:59 | 7 | It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 10 | It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 13 | The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational. |
| 00:00–23:59 | 14 | On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified. |
Events
1 M-class and 1 C-class flares observed by EOVSA at 17:52 and 20:25 UT. See dynamic spectra at this link.
Antenna availability: automatic assessment.
February 08¶
Observer: Caius Selhorst
Solar activity: Solar activity is moderate.
Calibrations
No Calibrations due to Hydraulic fault on 27m antenna.
Issues and outages
| Time (UT) | Antennas | Details |
|---|---|---|
| 00:00–23:59 | 7 | It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 10 | It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 13 | The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational. |
| 00:00–23:59 | 14 | On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified. |
Events
2 M-class and 2 C-class flares observed by EOVSA at 17:05, 17:36, 19:02 and 23:32 UT. See dynamic spectra at this link.
Antenna availability: automatic assessment.
February 09¶
Observer: Caius Selhorst
Solar activity: Solar activity is moderate.
Calibrations
No Calibrations due to Hydraulic fault on 27m antenna.
Issues and outages
| Time (UT) | Antennas | Details |
|---|---|---|
| 00:00–23:59 | 7 | It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 10 | It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 13 | The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational. |
| 00:00–23:59 | 14 | On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified. |
Events
2 M-class and 1 C-class flares observed by EOVSA at 00:09, 17:25 and 17:56. See dynamic spectra at this link.
Antenna availability: automatic assessment.
February 10¶
Observer: Caius Selhorst
Solar activity: Solar activity is moderate.
Calibrations
No Calibrations due to Hydraulic fault on 27m antenna.
Issues and outages
| Time (UT) | Antennas | Details |
|---|---|---|
| 00:00–23:59 | 7 | It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 10 | It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 13 | The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational. |
| 00:00–23:59 | 14 | On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified. |
Events
1 M-class and 5 C-class flares observed by EOVSA at 18:18, 20:46, 21:07, 22:47, 23:04 and 23:57. See dynamic spectra at this link.
Observations
Imported source block (date does not match record 2024-02-10)
Tohban notes for Wednsday, Feb 7 - Friday Feb 10:
Ant 4 FE Temp is out of range--no solution yet.
Ant 5 has low VPOL power probably due to DCM issue
Ant 7 has no VPOL power probably due to a failed optical link.
Ant 10 has no VPOL power probably due to a failed optical link.
Ant 10 FE Temp reporting bad temperature due to failed sensor.
Ant 14 has a hydraulic leak and transformer failure. No calibrations
until it can be repaired.
Report problems here:
Antenna availability: automatic assessment.
February 11¶
Observer: Caius Selhorst
Solar activity: Solar activity is moderate.
Calibrations
No Calibrations due to Hydraulic fault on 27m antenna.
Issues and outages
| Time (UT) | Antennas | Details |
|---|---|---|
| 4 | Ant 4 FE Temp is out of range--no solution yet. | |
| 5 | Ant 5 has low VPOL power probably due to DCM issue | |
| 00:00–23:59 | 7 | Ant 7 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 10 | Ant 10 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 10 | Ant 10 FE Temp reporting bad temperature due to failed sensor. | |
| 14 | Ant 14 has a hydraulic leak and transformer failure. No calibrations / until it can be repaired. | |
| ant3 and ant4 didn't start normaly, / They were sorted with a simple reboot after ~30min | ||
| 00:00–23:59 | 13 | The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational. |
| 00:00–23:59 | 14 | On Wednesday, Jan 10 at 00:00 UT, It was found that the 27m antenna had a hydraulic fluid leak and that the antenna would not move. Inspection is currently underway to determine location and cause of the leak. No calibrations until the fault is rectified. |
Events
1 C-class flare observed by EOVSA at 20:20 UT. See dynamic spectra at this link.
Antenna availability: automatic assessment.
February 12¶
Observer: Caius Selhorst
Solar activity: Solar activity is moderate.
Calibrations
The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified.
Issues and outages
| Time (UT) | Antennas | Details |
|---|---|---|
| 4 | Ant 4 FE Temp is out of range--no solution yet. | |
| 5 | Ant 5 has low VPOL power probably due to DCM issue | |
| 00:00–23:59 | 7 | Ant 7 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 10 | Ant 10 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 10 | Ant 10 FE Temp reporting bad temperature due to failed sensor. | |
| 14 | Ant 14 has a hydraulic leak and transformer failure. No calibrations / until it can be repaired. | |
| 00:00–23:59 | 13 | The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational. |
| 00:00–23:59 | 14 | The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified. |
Events
1 M-class and 1 C-class flares observed by EOVSA at 15:54 and 17:34 UT. See dynamic spectra at this link.
Antenna availability: automatic assessment.
February 13¶
Observer: Caius Selhorst
Solar activity: Solar activity is moderate.
Calibrations
No Calibrations due to the 27 m wrong receiver position. No calibrations until the fault is rectified.
Issues and outages
| Time (UT) | Antennas | Details |
|---|---|---|
| 00:00–23:59 | 7 | It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 10 | It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 13 | The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational. |
| 00:00–23:59 | 14 | The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified. |
Observations
Imported source block (date does not match record 2024-02-13)
Tohban notes for Tuesday Feb 14:
Ant 4 FE Temp is out of range--no solution yet.
Ant 5 has low VPOL power probably due to DCM issue
Ant 7 has no VPOL power probably due to a failed optical link.
Ant 10 has no VPOL power probably due to a failed optical link.
Ant 10 FE Temp reporting bad temperature due to failed sensor.
Ant 14 is now working again!
Report problems here:
13:20 UT: Phase tracking state was OFF, had to stop and restart the schedule
Ant14 focus rotation mechanism was not in place--morning calibration is bad.
Antenna availability: automatic assessment.
February 14¶
Observer: Caius Selhorst
Solar activity: Solar activity is moderate.
Calibrations
No Calibrations due to the 27 m wrong receiver position. No calibrations until the fault is rectified.
Issues and outages
| Time (UT) | Antennas | Details |
|---|---|---|
| 4 | Ant 4 FE Temp is out of range--no solution yet. | |
| 5 | Ant 5 has low VPOL power probably due to DCM issue | |
| 00:00–23:59 | 7 | Ant 7 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 10 | Ant 10 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 10 | Ant 10 FE Temp reporting bad temperature due to failed sensor. | |
| 14 | Ant 14 is now working again! | |
| 13:20 UT: Phase tracking state was OFF, had to stop and restart the schedule | ||
| 14 | Ant14 focus rotation mechanism was not in place--morning calibration is bad. | |
| 4 | Ant 4 Az permit (rebooted at 15:48 UT) | |
| 14 | Ant14 is back in operation after hydraulic hose replacement. / Data recording stopped at the start of the 22:14 Phasecal. Fixed by / stopping and restarting the schedule. / Data recording stopped at the completion of the 22:14 Phasecal. Fixed by / running $scan-start | |
| 00:00–23:59 | 13 | The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational. |
| 00:00–23:59 | 14 | The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified. |
Events
1 C-class flare observed by EOVSA at 17:55 UT. See dynamic spectra at this link.
Antenna availability: automatic assessment.
February 15¶
Observer: Caius Selhorst
Solar activity: Solar activity is moderate.
Calibrations
No Calibrations due to the 27 m wrong receiver position. No calibrations until the fault is rectified.
Issues and outages
| Time (UT) | Antennas | Details |
|---|---|---|
| 4 | Ant 4 FE Temp is out of range--no solution yet. | |
| 5 | Ant 5 has low VPOL power probably due to DCM issue | |
| 00:00–23:59 | 7 | Ant 7 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 10 | Ant 10 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 10 | Ant 10 FE Temp reporting bad temperature due to failed sensor. | |
| 14 | Ant 14 RX select has an Amp fault. Poor calibrations until the problem / can be identified and fixed. | |
| Prior to observations starting, Helios computer locked up. Restarted at / 16:10UT / Phase tracking was OFF around 18:38 UT, reset the schedule / * Phase tracking was off after the 20:00 UT Gaincal | ||
| 00:00–23:59 | 13 | The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational. |
| 00:00–23:59 | 14 | The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified. |
Antenna availability: automatic assessment.
February 16¶
Observer: Caius Selhorst
Solar activity: Solar activity is moderate.
Calibrations
No Calibrations due to the 27 m wrong receiver position. No calibrations until the fault is rectified.
Issues and outages
| Time (UT) | Antennas | Details |
|---|---|---|
| 4 | Ant 4 FE Temp is out of range--no solution yet. | |
| 5 | Ant 5 has low VPOL power probably due to DCM issue | |
| 00:00–23:59 | 7 | Ant 7 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 10 | Ant 10 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 10 | Ant 10 FE Temp reporting bad temperature due to failed sensor. | |
| 14 | Ant 14 RX select has an Amp fault. Poor calibrations until the problem / can be identified and fixed. | |
| 4 | Ant4 Az axis lock @ 16:00 UT. Rebooted the antenna controller to resume it / tracking / Phase tracking state was off after the 18:30 SOLPNTCAL. $scan-start resumed / phase tracking. / Reboot of ACC @ 20:40 UT | |
| 00:00–23:59 | 13 | The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational. |
| 00:00–23:59 | 14 | The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified. |
Events
1 M-class and 1 C-class flares observed by EOVSA at 16:20 and 22:05 UT. See dynamic spectra at this link.
Antenna availability: automatic assessment.
February 17¶
Observer: Caius Selhorst
Solar activity: Solar activity is moderate.
Calibrations
No Calibrations due to the 27 m wrong receiver position. No calibrations until the fault is rectified.
Issues and outages
| Time (UT) | Antennas | Details |
|---|---|---|
| 4 | Ant 4 FE Temp is out of range--no solution yet. | |
| 5 | Ant 5 has low VPOL power probably due to DCM issue | |
| 00:00–23:59 | 7 | Ant 7 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 10 | Ant 10 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 10 | Ant 10 FE Temp reporting bad temperature due to failed sensor. | |
| 14 | Ant 14 RX select has an Amp fault. Poor calibrations until the problem / can be identified and fixed. | |
| 22:32 UT: Phase tracking state is OFF after PHASECAL | ||
| 00:00–23:59 | 13 | The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational. |
| 00:00–23:59 | 14 | The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified. |
Antenna availability: automatic assessment.
February 18¶
Observer: Caius Selhorst
Issues and outages
| Time (UT) | Antennas | Details |
|---|---|---|
| 4 | Ant 4 FE Temp is out of range--no solution yet. | |
| 5 | Ant 5 has low VPOL power probably due to DCM issue | |
| 7 | Ant 7 has no VPOL power probably due to a failed optical link. | |
| 10 | Ant 10 has no VPOL power probably due to a failed optical link. | |
| 10 | Ant 10 FE Temp reporting bad temperature due to failed sensor. | |
| 14 | Ant 14 RX select has an Amp fault. Poor calibrations until the problem / can be identified and fixed. | |
| 22:32 UT: Phase tracking state is OFF after PHASECAL | ||
| 18:15 UT: Helios froze. Was off for the remainder of the day. |
Observations
No Observations during the day due to a fail in the Helios computer.
Antenna availability: automatic assessment.
February 19¶
Observer: Caius Selhorst
Solar activity: Solar activity is moderate.
Calibrations
No Calibrations due to the 27 m wrong receiver position. No calibrations until the fault is rectified.
Issues and outages
| Time (UT) | Antennas | Details |
|---|---|---|
| 4 | Ant 4 FE Temp is out of range--no solution yet. | |
| 5 | Ant 5 has low VPOL power probably due to DCM issue | |
| 00:00–23:59 | 7 | Ant 7 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 10 | Ant 10 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 10 | Ant 10 FE Temp reporting bad temperature due to failed sensor. | |
| 14 | Ant 14 RX select has an Amp fault. Poor calibrations until the problem / can be identified and fixed. | |
| 16:40: Observing resumed. Prior to this all computers had updates installed. / 18:20: Cycled ant6 FEM to reset temperature controller. / 18:30: Ant3 elevation axis lock. Rebooted the antenna controller. / 18:50: Ant10 off. Cycled crio power, restarted VIs and stowed antenna before / resuming tracking. / 19:20: Ant3 elevation axis lock. Rebooted the antenna controller. / 20:10: Phase tracking state is OFF. Reset the schedule / 21:50: Phase tracking state is OFF. Ran $scan-start | ||
| 00:00–23:59 | 13 | The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational. |
| 00:00–23:59 | 14 | The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified. |
Antenna availability: automatic assessment.
February 20¶
Observer: Caius Selhorst
Solar activity: Solar activity is moderate.
Calibrations
No Calibrations due to the 27 m wrong receiver position. No calibrations until the fault is rectified.
Issues and outages
| Time (UT) | Antennas | Details |
|---|---|---|
| 14 | The Ant 14 receiver is out of position, so use "No 27m" checkbox until further / notice. | |
| 4 | Ant 4 FE Temp is out of range--no solution yet. | |
| 5 | Ant 5 has low VPOL power probably due to DCM issue | |
| 00:00–23:59 | 7 | Ant 7 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 10 | Ant 10 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 10 | Ant 10 FE Temp reporting bad temperature due to failed sensor. | |
| 14 | Ant 14 RX select has an Amp fault. Poor calibrations until the problem / can be identified and fixed. | |
| 00:00–23:59 | 13 | The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational. |
| 00:00–23:59 | 14 | The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified. |
Events
1 C-class flare observed by EOVSA at 20:40 UT. See dynamic spectra at this link.
Antenna availability: automatic assessment.
February 21¶
Observer: Caius Selhorst
Solar activity: Solar activity is moderate.
Calibrations
No Calibrations due to the 27 m wrong receiver position. No calibrations until the fault is rectified.
Issues and outages
| Time (UT) | Antennas | Details |
|---|---|---|
| 14 | The Ant 14 receiver is out of position, so use "No 27m" checkbox until further / notice. | |
| 4 | Ant 4 FE Temp is out of range--no solution yet. | |
| 5 | Ant 5 has low VPOL power probably due to DCM issue | |
| 00:00–23:59 | 7 | Ant 7 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 10 | Ant 10 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 10 | Ant 10 FE Temp reporting bad temperature due to failed sensor. | |
| 14 | Ant 14 RX select has an Amp fault. Poor calibrations until the problem / can be identified and fixed. | |
| 00:00–23:59 | 13 | The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational. |
| 00:00–23:59 | 14 | The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified. |
Events
1 X-class and 4 C-class flares observed by EOVSA at 17:14, 18:17, 20:33, 22:41 and 23:04 UT. See dynamic spectra at this link.
Antenna availability: automatic assessment.
February 22¶
Observer: Caius Selhorst
Solar activity: Solar activity is moderate.
Calibrations
No Calibrations due to the 27 m wrong receiver position. No calibrations until the fault is rectified.
Issues and outages
| Time (UT) | Antennas | Details |
|---|---|---|
| 14 | The Ant 14 receiver is out of position, so use "No 27m" checkbox until further / notice. | |
| 4 | Ant 4 FE Temp is out of range--no solution yet. | |
| 5 | Ant 5 has low VPOL power probably due to DCM issue | |
| 00:00–23:59 | 7 | Ant 7 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 10 | Ant 10 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 10 | Ant 10 FE Temp reporting bad temperature due to failed sensor. | |
| 14 | Ant 14 RX select has an Amp fault. Poor calibrations until the problem / can be identified and fixed. | |
| 17:30 Common drive became inaccessable. A reboot of helios solvd the problem | ||
| 21:46 UT Phase tracking state is off, ran $scan-start | ||
| 00:00–23:59 | 13 | The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational. |
| 00:00–23:59 | 14 | The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified. |
Events
1 X-class, 1-M class and 1 C-class flares observed by EOVSA at 17:53, 20:40 and 22:32 UT. See dynamic spectra at this link.
Antenna availability: automatic assessment.
February 23¶
Observer: Caius Selhorst
Solar activity: Solar activity is moderate.
Calibrations
No Calibrations due to the 27 m wrong receiver position. No calibrations until the fault is rectified.
Issues and outages
| Time (UT) | Antennas | Details |
|---|---|---|
| 14 | The Ant 14 receiver is out of position, so use "No 27m" checkbox until further / notice. | |
| 4 | Ant 4 FE Temp is out of range--no solution yet. | |
| 5 | Ant 5 has low VPOL power probably due to DCM issue | |
| 00:00–23:59 | 7 | Ant 7 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 10 | Ant 10 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 10 | Ant 10 FE Temp reporting bad temperature due to failed sensor. | |
| 14 | Ant 14 RX select has an Amp fault. Poor calibrations until the problem / can be identified and fixed. | |
| 3 | 16:00 Ant3 Elevation Axis Lock | |
| 10 | 19:44 Shutdown Ant10 for the weekend so that RFI testing can be done on a / nearby LWA antenna. | |
| 00:00–23:59 | 13 | The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational. |
| 00:00–23:59 | 14 | The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified. |
Events
3 M-class and 3 C-class flares observed by EOVSA at 15:45, 16:17, 17:40, 20:25, 21:12 and 23:12 UT. See dynamic spectra at this link.
Antenna availability: automatic assessment.
February 24¶
Observer: Caius Selhorst
Solar activity: Solar activity is moderate.
Calibrations
No Calibrations due to the 27 m wrong receiver position. No calibrations until the fault is rectified.
Issues and outages
| Time (UT) | Antennas | Details |
|---|---|---|
| 14 | The Ant 14 receiver is out of position, so use "No 27m" checkbox until further / notice. | |
| 4 | Ant 4 FE Temp is out of range--no solution yet. | |
| 5 | Ant 5 has low VPOL power probably due to DCM issue | |
| 00:00–23:59 | 7 | Ant 7 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 10 | Ant 10 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 10 | Ant 10 FE Temp reporting bad temperature due to failed sensor. | |
| 14 | Ant 14 RX select has an Amp fault. Poor calibrations until the problem / can be identified and fixed. | |
| 00:00–23:59 | 13 | The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational. |
| 00:00–23:59 | 14 | The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified. |
Events
1 C-class flare observed by EOVSA at 17:16 UT. See dynamic spectra at this link.
Antenna availability: automatic assessment.
February 25¶
Observer: Caius Selhorst
Solar activity: Solar activity is moderate.
Calibrations
No Calibrations due to the 27 m wrong receiver position. No calibrations until the fault is rectified.
Issues and outages
| Time (UT) | Antennas | Details |
|---|---|---|
| 14 | The Ant 14 receiver is out of position, so use "No 27m" checkbox until further / notice. | |
| 4 | Ant 4 FE Temp is out of range--no solution yet. | |
| 5 | Ant 5 has low VPOL power probably due to DCM issue | |
| 00:00–23:59 | 7 | Ant 7 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 10 | Ant 10 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 10 | Ant 10 FE Temp reporting bad temperature due to failed sensor. | |
| 14 | Ant 14 RX select has an Amp fault. Poor calibrations until the problem / can be identified and fixed. | |
| 00:00–23:59 | 13 | The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational. |
| 00:00–23:59 | 14 | The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified. |
Events
1 M-class flare observed by EOVSA at 17:06 UT. See dynamic spectra at this link.
Antenna availability: automatic assessment.
February 26¶
Observer: Caius Selhorst
Solar activity: Solar activity is moderate.
Calibrations
No Calibrations due to the 27 m wrong receiver position. No calibrations until the fault is rectified.
Issues and outages
| Time (UT) | Antennas | Details |
|---|---|---|
| 14 | The Ant 14 receiver is out of position, so use "No 27m" checkbox until further / notice. | |
| 4 | Ant 4 FE Temp is out of range--no solution yet. | |
| 5 | Ant 5 has low VPOL power probably due to DCM issue | |
| 00:00–23:59 | 7 | Ant 7 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 10 | Ant 10 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 10 | Ant 10 FE Temp reporting bad temperature due to failed sensor. | |
| 14 | Ant 14 RX select has an Amp fault. Poor calibrations until the problem / can be identified and fixed. | |
| 18:53 Phase tracking was off. Restarted with $scan-start | ||
| 23:50 Helios common drive became inaccessable. Restarted Helios. | ||
| 00:00–23:59 | 13 | The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational. |
| 00:00–23:59 | 14 | The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified. |
Events
2 C-class flares observed by EOVSA at 20:44 and 21:53 UT. See dynamic spectra at this link.
Antenna availability: automatic assessment.
February 27¶
Observer: Caius Selhorst
Solar activity: Solar activity is moderate.
Calibrations
No Calibrations due to the 27 m wrong receiver position. No calibrations until the fault is rectified.
Issues and outages
| Time (UT) | Antennas | Details |
|---|---|---|
| 14 | The Ant 14 receiver is out of position, so use "No 27m" checkbox until further / notice. | |
| 4 | Ant 4 FE Temp is out of range--no solution yet. | |
| 5 | Ant 5 has low VPOL power probably due to DCM issue | |
| 00:00–23:59 | 7 | Ant 7 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 10 | Ant 10 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 10 | Ant 10 FE Temp reporting bad temperature due to failed sensor. | |
| 14 | Ant 14 RX select has an Amp fault. Poor calibrations until the problem / can be identified and fixed. | |
| 21:37 Data recording did not start. restarted at 22:33 by issuing $scan-start | ||
| 23:23 Frequency tuning stopped. Stopped and restarted the schedule to reset. | ||
| 00:00–23:59 | 13 | The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational. |
| 00:00–23:59 | 14 | The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified. |
Antenna availability: automatic assessment.
February 28¶
Observer: Caius Selhorst
Solar activity: Solar activity is moderate.
Calibrations
No Calibrations due to the 27 m wrong receiver position. No calibrations until the fault is rectified.
Issues and outages
| Time (UT) | Antennas | Details |
|---|---|---|
| 14 | The Ant 14 receiver is out of position, so use "No 27m" checkbox until further / notice. | |
| 4 | Ant 4 FE Temp is out of range--no solution yet. | |
| 5 | Ant 5 has low VPOL power probably due to DCM issue | |
| 00:00–23:59 | 7 | Ant 7 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 10 | Ant 10 has no VPOL power probably due to a failed optical link.; It has no VPOL power probably due to a failed optical link |
| 10 | Ant 10 FE Temp reporting bad temperature due to failed sensor. | |
| 14 | Ant 14 RX select has an Amp fault. Poor calibrations until the problem / can be identified and fixed. | |
| Late start due to ACC lock-up. | ||
| 3 | Ant 3 is "stuck" at startup. Tracking at 16:17 UT | |
| 18:37 UT Phase tracking stopped. Restarted at 19:40 UT | ||
| 00:00–23:59 | 13 | The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational. |
| 00:00–23:59 | 14 | The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified. |
Events
1 M-class flare observed by EOVSA at 18:04 UT. See dynamic spectra at this link.
Antenna availability: automatic assessment.
February 29¶
Observer: Caius Selhorst
Solar activity: Solar activity is moderate.
Calibrations
No Calibrations due to the 27 m wrong receiver position. No calibrations until the fault is rectified. Most of the day without observation due to a memory test on Helios.
Issues and outages
| Time (UT) | Antennas | Details |
|---|---|---|
| 00:00–23:59 | 7 | It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 10 | It has no VPOL power probably due to a failed optical link |
| 00:00–23:59 | 13 | The solar cell batteries and cables were replaced. But, due to the 27m problems, the antenna is not full operational. |
| 00:00–23:59 | 14 | The hydraulic fault on 27m antenna was solved. But, the receiver is out of position. No calibrations until the fault is rectified. |
Observations
Imported source block (date does not match record 2024-02-29)
Tohban notes for Wedesday Feb 28:
The Ant 14 receiver is out of position, so use "No 27m" checkbox until further
notice.
Ant 4 FE Temp is out of range--no solution yet.
Ant 5 has low VPOL power probably due to DCM issue
Ant 7 has no VPOL power probably due to a failed optical link.
Ant 10 has no VPOL power probably due to a failed optical link.
Ant 10 FE Temp reporting bad temperature due to failed sensor.
Ant 14 RX select has an Amp fault. Poor calibrations until the problem
can be identified and fixed.
Report problems here:
Very Late start due to Helios failure. Ran disk checks and memory checks.
Memory tests failed.
Ant 2 is "stuck" at startup. Two power-cycles of the antenna were
required. Tracking at 22:36 UT
Phase Tracking did not start. Ran $scan-start
Antenna availability: automatic assessment.